+1 973 536 2331

CD AUTOMATION UK LTD RE3600-61APWA3021 in GERMANY

Get the best sales prices in GERMANY for CD AUTOMATION UK LTD RE3600-61APWA3021 from Impexron GmbH.

Product: RE3600-61APWA3021
Country: Germany
Description: Thyristorsteller
Techical specification: Serie REVO CD3000E mit integrierter Sicherung und integriertem Keypad. Typ: RE3 A-Nr.: Typ: RE-3-A-B-C-D-E-F-G-H-I-J-K (RE) Serienkennzeichnung Serie CD3000E (3) Anzahl der Phasen: 3-Phasen-Steller (Drehstrom) (A) Nennstrom (Imax) bei 45°C Umgebungstemperatur 025: 25A (116x316x187mm) 035: 35A (116x316x187mm) 045: 45A (116x316x187mm) 075: 75A (116x316x187mm) 100: 100A (137x440x270mm) 125: 125A (137x440x270mm) 150: 150A (137x440x270mm) 225: 225A (262x440x270mm) 300: 300A (262x520x270mm) 350: 350A (262x520x270mm) 400: 400A (262x520x270mm) 450: 450A (262x520x270mm) 500: 500A (262x520x270mm) (B) Lastspannung (Umax) 4: 480V 6: 600V (C) Hilfsspannung (Elektronik) 1: 110V 2: 230V (D) Ansteuerung (Stellgrößensignal) V: 0...10Vdc A: 4...20mA K: 10k Poti R: RS485 (E) Betriebsart Z: ZC - Nulldurchgangschaltend C: SC - Einzelimpuls B: BF - Puls Paket, bitte die Anzahl der Vollwellen angeben, die bei 50% Stellgröße ausgegeben werden sollen. Bereich: 1....255 J: S+BF - Rampenfunktion + Puls Paket D: DT+BF - Verzögerungsbetrieb + Puls Paket P: PA - Phasenanschnittsteuerung E: S+PA - Rampenfunktion + Phasenanschnitt (E) Rückführung 0: ohne U: Spannungsrückführung I: Stromrückführung W: Leistungsrückführung (F) Istwertausgang A: 4..20 mA Lastspannung, Laststrom und Lastleistung V: 0...10 V Lastspannung, Laststrom und Lastleistung (G) Lüfterspannung 3: gleich der Hilfsspannung (H) Approbationen 0: CE- Zeichen L: cUL für den amerikanischen Markt (I) Bedienungsanleitung (Sprache) 0: ohne Anleitung 1: Italienisch 2: Englisch 3: Deutsch 4: Französisch (J) Schalungsart 1: Ohmsche Last, Dreieckschaltung 2: Ohmsche Last, Sternschaltung, 3 Leiter 7: Ohmsche Last, Sternschaltung, 4 Leiter, mit Null 3: Transformator, Dreieckschaltung 4: Transformator, Sternschaltung 5: Transformator, Sternschaltung, 4 Leiter, mit Null 6: Ohmsche Last, offenes Dreieck (K) Lastnennstrom Bitte den Nennstrom und Nennspannung der Last hier eintragen
Condition: New (Unused)

If you need RE3600-61APWA3021 to recover your broken equipment or machines or for new applications,  you are on the right website.

You can get help from our expert regarding sales prices for CD AUTOMATION UK LTD - RE3600-61APWA3021 Thyristorsteller in Germany. 

By buying products of CD AUTOMATION UK LTD and using our service you get high quality products with cheap prices. 

We know time is expensive, so let us find the best prices for spare parts and components for you. 

We are not an official representative of CD AUTOMATION UK LTD, but we are selling their products at good prices. 

Purchase high quality spare parts of CD AUTOMATION UK LTD - RE3600-61APWA3021 Thyristorsteller in Germany on cheap prices. 

During the past years we managed to develop enough to satisfy the requirements of our customers. 

Contact us by e-mail or just fill out our RFQ form online. 

Our company is not an authorized distributor or representative for this brand. We are a reseller company for this brand.

Other products from CD AUTOMATION UK LTD

22557-59947-001 Original Spare Part
CD AUTOMATION UK LTD
CD 3000S-3PH-30A-460V-SSR Thyristor switch
CD AUTOMATION UK LTD
CD3000 45/60/ 75A regulator heater
CD AUTOMATION UK LTD
CD3000A SSR Only
CD AUTOMATION UK LTD
CD3000M 2PH/150A/380V/480V/170:265V/SSR/ZC/IF/HB/FAN110V/EM CD3000M 2 Phases unit 150 Amps / 380V Operating voltage / 480Volts supply voltage 170 to 265 Volts auxiliary power supply SSR Input Zero crossing firing 3 x Internal fuses included Heater Break alarm 110V power supplied fan English Manual
CD AUTOMATION UK LTD
CD3000M 2PH/75A/380V/480V/170:265V/SSR/ZC/NF/HB/110VFAN/EM CD3000M 2 Phases unit 75 Amps / 380V Operating voltage / 480Volts supply voltage 170 to 265 Volts auxiliary power supply SSR Input Zero crossing firing Without external fuses Heater Break alarm 110V Fan English Manual
CD AUTOMATION UK LTD
CD3000M 3PH 25 KW Original Spare Part
CD AUTOMATION UK LTD
CD3000M 3PH 44 KW 44kw CD3000M 3PH
CD AUTOMATION UK LTD
CD3000M 3PH 56 KW 56kw CD3000M 3PH
CD AUTOMATION UK LTD
CD3000M 3PH 65KW 65kw CD3000M 3PH
CD AUTOMATION UK LTD
CD3000S 1PH/45A/-/480V/12:24V /SSR/ZC/NF/HB/EM CD3000S 1 Phase unit 1PH 45 Amps / Operating voltage not specified / 480V max Voltage 12 to 24 Volts auxiliary power supply SSR Input Zero crossing firing Without external fuses Heater Break alarm with SSR input English Manual
CD AUTOMATION UK LTD
CD3000S-2PH 480V-75A-480V-SSR SSR coil:5-30V
CD AUTOMATION UK LTD
CD3000S-2PH-10A-480V-SSR Schalting; 2-Phasensteller,Nulldurchgangsschalter
CD AUTOMATION UK LTD
CD3000S-2PH-15A-480V-SSR Thyristor switch
CD AUTOMATION UK LTD
CD31.CT025/0,05W Current Transformer Ip / Is-Vs 25/0.05 2V
CD AUTOMATION UK LTD
CD32000035480460CL .CD3200-35A 480V-460V-CL Modulbauweise besteht aus : 1x CD3200 Ansteuereinheit 1xCD3S0035480PA Thyristorsteller 1xCD31.CT.50A/0,05 A Stromwandler
CD AUTOMATION UK LTD
CD3200-15A-480V-170:265V-0/5V-PA-V-NF-UL -
CD AUTOMATION UK LTD
CD3M10300480230 Original Spare Part
CD AUTOMATION UK LTD
CD3M20400480460HB Original Spare Part
CD AUTOMATION UK LTD
CD3M30300480460HB Original Spare Part
CD AUTOMATION UK LTD

Impexron GmbH

Gönningerstr. 99, 72793 Pfullingen, Germany

Phone:
+4971213059012

Fax:
+49 3222 246 8634