Specifications:
Power: DC24V
Power Consumption: 45.6W
Discharge pressure: 8MPa (Only for LHL System)
Maximum discharging time: Below 7m 30s
Interval time: 3 times discharging time
Wiring method: Terminal connection
Manual override switch: With(Optional: Only PDI system)
Grease level switch :With
Solenoid cover: Non combustible plastic( UL94-V0)
IPRated: IP54
CERated: With
Pump air bleeding: With restriction
Weight: 2.0kg(Manual override switch 2.1kg)
Environmental conditions:
● Use recommended cartridge greases.
● Never use molybdenum disulfide-contained grease.
● Use lithium greases. (Contact us for consultation when other than lithium grease is used.)
● Do not use any greases containing substances that attack brass and rubber.
● When replacing cartridge, take care not to let foreign matter in the .
● Avoid continuous operation.
● After changing the cartridge, bleed the air inside the pump by opening the air bleeding valve.
Model and Part Numbers:
Yusaki LLC
584-0023 2-2-16 Wakamatsuchohigashi, Tondabayashi City, Osaka Prefecture
Phone:
+81 721-26-8450
Fax:
+81 721-26-7242
E-mail:
sales@yusaki.jp